Your free home assessment
James visits, gives a straight answer on suitability and a fixed estimate on the spot.
Heat pumps for bungalows work well when the design starts from the bungalow itself: every room sits under the roof and on the ground, and the cylinder needs a home on the one floor you have. If yours still runs on an oil boiler, those three facts shape the system more than the make on the box.
Key Takeaways
- A bungalow suits an air source heat pump when a room-by-room heat loss survey of that bungalow sizes it, never its floor area or its old boiler.
- Every room in a bungalow loses heat through the ceiling and the floor, so loft insulation and floor construction carry a lot of weight in the sizing.
- Oil and LPG homes in Devon typically come out somewhere between 4 and 10 kW of heat loss, and your own survey sets your figure.
- If you qualify, the grant takes £7,500 off; oil and LPG homes with no mains gas get £9,000 until 31 March 2027.
- In East Devon bungalows from Exmouth to Seaton, the first free visit looks at where the cylinder and outdoor unit could go before anyone talks about kilowatts.
An oil-heated bungalow puts three decisions on one floor: how much heat leaves through the loft and the ground, where a cylinder fits, and which wall takes the outdoor unit when the bedrooms sit next to the garden. Our page on replacing the oil boiler in a bungalow covers the swap itself as a service.
Are Heat Pumps Good for Bungalows?
Yes, when it is detached, heated by oil or LPG, with a garden for the outdoor unit and a cupboard or utility room for the cylinder. A heat pump sends cooler water round the radiators for longer than an oil boiler does, so it suits a house that holds its heat.
James chooses the heat pump and cylinder for each property from more than one manufacturer, and Ideal is a make he fits often. So the answer to “which heat pump is best for a bungalow” comes out of your survey, along with the size.
Signs your bungalow suits a heat pump
- Detached, with space outside for the outdoor unit
- Heated by oil or LPG today
- A cupboard, utility room or garage wall that could take a cylinder
- Loft insulation in place, or planned before the install
- You own it (the grant needs an owner)
What Size Heat Pump Does a Bungalow Need?
Illustration: the outdoor unit in the garden, pipes through the wall to the hot water cylinder, the wall controller and a radiator under the window.
A bungalow’s heat loss comes from its own walls, windows, floor and roof, measured room by room at the design temperature for your postcode. On one storey, every room has the loft above it and the ground below, so loft insulation and the floor count for more in the sum than they would in a two-storey house with the same floor area.
Two bungalows of the same size on the same road can need different heat pumps for that reason. A well-filled loft and newer windows pull the figure down; a thin loft and a draughty conservatory push it up. James measures it at the heat loss survey (free if you go ahead with the install; £250 plus VAT if you decide not to), and the kilowatt figure comes from those measurements, never from the old boiler’s rating.
Where the heat goes
Bungalow
Roof above every room, ground under every room.
Two-storey house, same floor area
Roof above the upstairs rooms, ground under the downstairs ones.
Your survey measures how much heat leaves; this shows where.
Finding Room for the Cylinder in a Bungalow
A heat pump stores your hot water in a cylinder, so it needs a place on the floor you live on. An existing airing cupboard can take the new one if it fits, and the towels find another shelf; if a combi took the old cylinder away, a utility room, a garage wall or an outbuilding close to the house can. James looks at the spot at the first visit, because it also sets the pipe route to the outdoor unit.
In a bungalow the loft looks like spare space, and it comes last on the list. Stored water weighs a kilogram a litre, so a 200 litre cylinder puts 200 kg on the ceiling joists before you count the cylinder, and the loft is the coldest place in the house to keep hot water and the awkward one to service. Our guide to choosing and sizing the cylinder covers the types and the litres.
Where a bungalow cylinder can go
Airing cupboard
The smallest change, if the space is big enough
Utility room
Room for the cylinder and its valves together
Garage or outbuilding
Lagged pipes and a frost-safe corner
Loft
Only with joists strong enough and a way in for servicing
Radiators, Loft Pipework and Underfloor Heating in a Bungalow
Illustration: a living room with a panel radiator under the window.
The survey checks each radiator against its room’s heat loss at a heat pump’s cooler water temperature and lists the ones that need to be bigger.
If your bungalow’s heating pipes run through the loft and drop to each radiator, they lose heat on the way, and that counts for more with a heat pump’s long, cool running. The design checks their size against the flow a heat pump needs and their lagging above the insulation. Underfloor heating suits a heat pump because it spreads cooler water across the whole floor, and you don’t need it: it makes sense where you are lifting floors anyway, for a kitchen refit or an extension.
If your pipes run through the loft
Ask at the survey which runs stay, which get bigger, and how the lagging sits above the loft insulation.
Placing the Outdoor Unit Around a Single-Storey Home
In a bungalow your bedrooms sit beside the garden where the outdoor unit goes, so its position has to suit your own windows as well as the neighbours’. A side or rear wall close to the cylinder is the usual spot.
In England, a heat pump fitted under permitted development has to pass the MCS 020 a) sound calculation: no more than 37 dB at a point 1 metre outside a neighbour’s habitable-room window or door. Eco Pro works it out for every design, so the position you agree with James has already been checked against next door.
Before you and James fix the unit position
- Your own bedroom windows
- The neighbours’ windows and doors (the 37 dB test)
- The pipe run to the cylinder
- Clear air around the fan, and room to service it
- Where the condensate drains
Heat Pumps for Bungalows: Cost and the Grant for Oil and LPG Homes
The cost of a heat pump for a 2 bed bungalow, or a 3 bed one, turns on four things: the heat pump size, the cylinder, the radiator changes and the loft pipework. The free home visit ends with a fixed estimate for yours, and our guide to what a heat pump costs in Devon after the grant sets out what drives the number.
If you qualify, the Boiler Upgrade Scheme takes £7,500 off an air source heat pump, and until 31 March 2027 it adds £1,500, making £9,000, when oil or LPG heats your home and it has no mains gas connection. You need to own the property; Eco Pro applies for you, and the grant comes off the quote and the invoice. Installation is zero-rated for VAT until 31 March 2027, and our Budleigh Salterton page works through the grants and costs for homes in that town.
£9,000
Oil or LPG home with no mains gas, until 31 March 2027.
If you qualify£7,500
Air source heat pump grant, if you qualify.
0% VAT
On installation until 31 March 2027.
Source: gov.uk Boiler Upgrade Scheme and HMRC VAT Notice 708/6, read 26 Oct 2026. England and Wales.
Fitting a Heat Pump in a Bungalow
In a bungalow every room the fitting touches is a room you live in, and the loft hatch is the way into most of the pipe runs, so the hatch, the cylinder spot and the wall for the unit are the three places to clear first. James designs the system, commissions it and hands it over; one of the two-man install teams Eco Pro works with does the fitting to his design. He works from Exmouth along the coast to Seaton and inland across East Devon, and he takes on one or two jobs at a time.
One floor, three places to clear
The loft hatch, the cylinder spot and the wall you have in mind for the unit. Everything else follows from those three.
Frequently Asked Questions
Illustration: a thermostatic radiator valve on a copper pipe beside a panel radiator.
Yes, when a room-by-room heat loss survey sizes the system. A detached bungalow on oil or LPG, with outdoor space and room for a cylinder, is a strong candidate.
Find out whether yours fits at a free home assessment.
The one sized for your bungalow’s measured heat loss, with a cylinder that fits your space. James chooses the make for each property; Ideal is one he fits often, and Eco Pro is not tied to it.
Ask James which makes suit your house at a free home assessment.
It depends on the heat pump size, the cylinder, the radiator changes and the pipework. If you qualify, the grant comes off upfront: £7,500, or £9,000 for oil and LPG homes with no mains gas until 31 March 2027.
Get a fixed estimate for your bungalow at a free home assessment.
Your heat loss survey sets it, room by room. Many oil and LPG homes in Devon fall somewhere between 4 and 10 kW, and a bungalow’s loft and floor insulation move the figure up or down.
Book the first step towards your figure with a free home assessment.
Only with joists strong enough for a kilogram per litre of water and a safe way in for servicing. A cupboard, utility room or garage comes first.
Show James your options at a free home assessment.
No. Radiators sized for a heat pump’s cooler water do the job. Underfloor heating makes sense where floors are coming up anyway.
Talk through any building plans at a free home assessment.
Yes, if you qualify for the standard grant, oil heats it and it has no mains gas connection, until 31 March 2027. Eco Pro applies, and the grant comes off your quote and invoice.
Check your bungalow qualifies at a free home assessment.
About a week on site, starting on a Monday with commissioning on the Thursday or Friday.
Start planning your dates at a free home assessment.
Start With One Visit to Your Bungalow
Show James the loft hatch, the airing cupboard and the wall you had in mind for the unit, and he will tell you which ones work and leave you a fixed estimate. The room-by-room survey comes after, if you go ahead.
Book my free home assessmentPrefer to talk it through first? Ring 01395 202030. James answers, and he is the person who will price the job.
★★★★★
“The heat pump is almost silent, which was something we were worried about, and the results have been fantastic. We’re lovely and warm and always have plenty of hot water.”
Grace Murphy · Google review