A heat pump hot water cylinder stores water your heat pump has already warmed, because a heat pump can’t heat water the instant you open a tap the way a combi boiler does. So when an oil or LPG combi leaves a Devon home, a new heat pump cylinder needs a place of its own in the house. Where a regular boiler feeds a copper tank, that tank usually goes too, unless its coil is rated for heat pump temperatures.
Key Takeaways
- A Devon home leaving an oil or LPG combi needs stored hot water, because a heat pump warms water ahead of time rather than as the tap opens.
- Your old tank says little about the new one: Vaillant’s guide puts three to four people at 175 to 200 litres, whatever stood there before.
- Extra litres cost you floor strength and space, since 200 litres of stored water weighs 200 kg before you count the cylinder.
- Hot water safety lives in the design paperwork, which names your storage temperature and a regular lift to 60°C to kill legionella.
- In older Devon cottages and bungalows, finding a cupboard, corner or wall for the cylinder often decides more than the choice of make.
If one of you showers at seven and the other runs a bath at ten past, the cylinder decides whether the second person gets hot water. James fixes its size, position and settings at design, before anything is ordered.
Why a Heat Pump Needs a Hot Water Cylinder, and Why the Combi Goes
Illustration: the outdoor unit in the garden, pipes through the wall to the hot water cylinder, the wall controller and a radiator under the window.
A combi burns oil or gas fast enough to heat mains water as it flows, so hot water reaches the tap in seconds. An air source heat pump moves heat from the outside air into water at a gentler pace, so it heats a store of water ahead of time, and that store is the cylinder, sometimes called a heat pump hot water tank.
So yes, air source heat pump hot water comes from the same unit that heats the house, and a standard air-to-water installation needs a cylinder to do it. A valve sends the heat pump’s warm water either round the radiators or through the cylinder’s coil, one job at a time.
Oil or LPG combi
- Hot water Heated as it flows, from cold mains
- Storage None
Heat pump and cylinder
- Hot water Heated ahead of time and stored
- Storage A cylinder sized for your household
What Makes a Heat Pump Cylinder Different From the One You Have
A boiler sends hotter water through its cylinder coil than a heat pump can, so a short coil does the job. Cooler heat pump water gives up its heat more slowly, so a heat pump cylinder carries a larger coil (Vaillant’s guide makes the same point), and the MCS best practice guide says any cylinder used with a heat pump must have a heat exchanger suited to the heat pump’s temperatures and output.
That coil decides whether an existing cylinder can stay, and its rating sits on the data plate. We fit well-insulated, heat-pump-specific cylinders, and an unvented one gives you mains pressure at the shower.
What Size Heat Pump Hot Water Cylinder Does Your Household Need?
Illustration: heat pumps in a range of sizes beside a cylinder and a wall thermostat.
Heat pump cylinder size follows the people in the house and how they use hot water, which makes the old tank a poor guide. Vaillant publishes a simple rule for its heat pump cylinders.
Two bathrooms, a nightly bath or a power shower push you toward the top of your band, and a 300 litre heat pump cylinder suits a big household with heavy use.
The MCS guide notes that no agreed method yet exists for sizing a heat pump for hot water, and it asks the installer to discuss your hot water use and tell you the design reheat time. Expect questions at the survey about who showers when and how often family come to stay.
Finding Room for a Heat Pump Hot Water Cylinder in an Older Devon Property
If a combi replaced your old tank, the airing cupboard may now hold towels, and a cob cottage or narrow terrace may never have had a cupboard big enough. A utility room, a garage wall or the space under the stairs can take a cylinder instead, and slimline or horizontal models fit narrow spaces and low lofts, such as the older houses near the quay in Topsham. The floor has to carry a kilogram for every litre.
Will it fit? Measure these before the visit
-
The space width, depth, and floor-to-ceiling height of the cupboard or corner
-
The way in doorways, stairs and any loft hatch on the route
-
The floor solid concrete, or boards on joists
-
The outside wall how far the nearest one is, for the pipes from the outdoor unit
-
The discharge route a way outside for the safety pipe an unvented cylinder needs
Unvented, Pre-Plumbed or Integrated: The Cylinders You Will Be Offered
Three labels turn up on quotes. We fit Ideal’s pre-plumbed heat pump cylinders often, but Eco Pro is not tied to one maker, and James chooses the air source heat pump cylinder for each house at design as part of how we design and fit an air source heat pump.
Unvented heat pump cylinder
Fed straight from the mains with no loft tank, and notifiable work under Part G.
Mains pressurePre-plumbed heat pump cylinder
Arrives with its expansion vessel, valves and controls fitted at the factory.
Parts fitted at the factoryIntegrated cylinder
Either one casing for the cylinder and the heat pump’s indoor parts, or a water-only tank that can’t replace a boiler.
Two meaningsHow Hot the Water Gets, and the Weekly Legionella Cycle
The MCS best practice guide recommends a hot water flow temperature of 55°C or more from the heat pump. Legionella bacteria stop multiplying above 50°C and die above 60°C, so where the everyday store sits lower, the system lifts it to 60°C on a regular cycle, typically weekly. Your MCS design has to state the storage temperature and how that cycle runs.
Each extra degree in the store makes the heat pump work harder, so a good design holds the everyday temperature where safety needs it and times reheats around your tariff. Our guide to heating your water on a cheaper overnight rate explains how those tariffs split the day.
The weekly cycle
Your design pack records your everyday storage temperature and this weekly lift.
60°C
Pasteurisation. Above this, the MCS guide says legionella bacteria die. MCS gives once a week as the usual interval.
If the settings ever change, ask your installer to put both back.
Will You Run Out of Hot Water? Reheat Times in Real Life
You run out when the house draws more hot water than the cylinder holds before the heat pump can reheat it. Ideal publishes heat-up times for its heat pump cylinders: its 148 and 170 litre models go from 10°C to 50°C in about 22 minutes, and its 279 litre model in about 35. Yours depends on the heat pump’s output and your design temperatures, and your installer should tell you that design reheat time.
No hot water? Check these before you ring
The schedule
Hot water may be switched off in the controller, or a holiday setting left on.
The target temperature
Someone may have turned the cylinder setting down.
The boost
Press it and give the heat pump time to reheat the store.
Still cold?
A stuck valve or a fault code needs an engineer: heat pump servicing and repairs cover systems we didn’t install.
Frequently Asked Questions
Yes, for a standard air-to-water system. A heat pump heats water more slowly than a combi, so it warms a stored cylinder ahead of time and you draw from that.
At a free home assessment, James shows you where a cylinder could sit.
Only if its coil suits the heat pump’s temperatures and output, as the MCS guide requires. James checks its data plate first.
Book a free home assessment and have your old tank checked on the day.
Vaillant’s sizing guide puts three to four people at 175 to 200 litres. Two bathrooms or a bath most evenings push that up, and the survey settles your figure.
Talk James through your showers and baths at a free home assessment.
The MCS guide recommends heating it at a 55°C flow temperature or more, and the store goes up to 60°C on a regular cycle, usually once a week.
Ask how the settings fit your tariff at a free home assessment.
A cylinder sized for your household, with reheats timed before the busy periods, covers ordinary use. A boost button and a backup immersion heater cover the heavy days.
Tell James about your busiest mornings at a free home assessment.
Yes. Fitting one is notifiable building work under Part G. An installer registered with a competent person scheme self-certifies it, and you receive a compliance certificate.
James checks the discharge pipe route at the free home assessment.
A utility room, a garage, under the stairs, or a loft with a floor strong enough for the weight. Slimline and horizontal models suit narrow spaces and low lofts.
Show James your spare corners at a free home assessment.
Settle Your Cylinder at the First Visit
The cylinder is the part of a heat pump system you’ll walk past every day. One free home assessment covers where it can go, roughly how big it needs to be (the heat loss survey fixes the exact size) and if your old tank could stay, and James answers those questions standing in the room with you.
Book my free home assessmentPrefer to talk it through first? Ring 01395 202030. James answers, and he is the person who will price the job.
★★★★★