Your running costs depend less on the thermostat than on the heat pump flow temperature: how hot the water is as your heat pump sends it round the radiators. Keeping that water as cool as your rooms allow is the most efficient way to run an air source heat pump.
Key Takeaways
- Turning the thermostat up asks for a warmer room, and it can’t make the water hotter than the limits your installer set.
- In the MCS guide’s worked example, running a whole system 10°C hotter to keep small radiators upstairs cost about 15% of its efficiency.
- In an older Devon home, the radiators fitted for an oil boiler decide how low the flow can go, and upsizing a few can lower it.
- Weather compensation does much of the saving on its own: on the MCS guide’s example curve, the flow falls from 55°C to about 43°C at 7°C outside.
- If bills run high, compare the controller’s maximum flow temperature with your design paperwork before you blame the heat pump.
You may wonder whether a stone cottage copes with a heat pump’s cooler water. Or you own one already, and the bills came in higher than you were told. Both questions come back to this setting, and the figures here come from the MCS and RECC best practice guide for installers.
What Heat Pump Flow Temperature Means, and Why It Is Not Your Thermostat
Illustration: a living room with a panel radiator under the window.
Your thermostat sets the room temperature you want. The heating flow temperature is a separate number: how hot the water is as it leaves the heat pump on its way to the radiators. The return temperature is that same water coming back, a few degrees cooler once the radiators have passed its heat into the rooms.
An oil boiler heats water hot and fast in short bursts. A heat pump does its best work sending cooler water round for longer, within limits your installer set at commissioning, so turning the thermostat up asks for a warmer room without making the water any hotter than those settings allow.
Why a Lower Flow Temperature Costs Less to Run
A heat pump moves heat out of the outside air and into water, and the smaller the gap between the two temperatures, the less electricity each unit of heat costs. The MCS and RECC guide tells installers that a cooler flow temperature raises heat pump efficiency, and you can’t warm the January air, so the design works on the water. The guide’s worked example, a house with underfloor heating downstairs and radiators upstairs, shows what a hotter design costs.
Designed for about 45°C
- Radiators Sized a little larger upstairs
- Underfloor Runs at its 45°C design
- Efficiency The baseline in the guide’s example
Forced up to 55°C
- Radiators Kept small upstairs
- Underfloor Water blended down from 55°C to 45°C
- Efficiency About 15% lower across the whole system
Worked example from MCS and RECC, Domestic Heat Pumps: A Best Practice Guide, page 25. It shows the direction of the effect, and your own house will differ.
What Flow Temperature Should a Heat Pump Run At?
Illustration: a dining room with a long double-panel radiator under the window.
The MCS and RECC guide gives installers a range for air source heat pump flow temperature in place of one number, with radiators ideally sized so the top of the range covers the coldest day the system was designed for. On a mild day the system should run well below that maximum. James designs a house in Wiveliscombe, 126 metres up at the foot of the Brendon Hills, to a colder day than one at sea level, as our Wiveliscombe page explains.
Your existing radiators decide how low that maximum can go. The survey checks each one, and our guide on whether your radiators can cope at a lower temperature explains what changes when some of them can’t.
The heat pump temperature range the MCS guide suggests
Treat these as design guidance for installers. Your own maximum comes from each room’s measured heat loss, and it can sit higher where a radiator can’t grow.
30°C to 45°C
A minimum flow temperature and a design-day maximum, with radiators ideally sized for the top figure.
A heat pump runs cooler water than a boiler, so each radiator gives out less heat. Our room-by-room survey checks every radiator against the heat the room needs.
Weather Compensation: The Setting That Does Most of the Work
Weather compensation reads the outdoor temperature and lowers the flow temperature as the weather warms, because radiators don’t need full output on a mild day. MCS requires it to be available on every space heating system, though it leaves the set-up to the installer.
Two houses on the same road in Exmouth can need different curves, because each comes from that house’s heat loss and radiator schedule.
Example weather compensation curve
Flow temperature (°C)
Outdoor temperature (°C)
Example heat pump weather compensation curve from MCS and RECC, Domestic Heat Pumps: A Best Practice Guide, page 26. Your installer sets your own curve at commissioning.
Heating Versus Hot Water: Two Different Flow Temperatures
Illustration: the outdoor unit in the garden, pipes through the wall to the hot water cylinder, the wall controller and a radiator under the window.
Heat pump water temperature for the cylinder sits higher than for the radiators. The MCS guide says the flow for hot water should ideally reach 55°C or more, which helps stop legionella bacteria multiplying in the cylinder, and that keeping the heating and hot water flow temperatures separate gets the best efficiency, above all in heating mode.
So the heat pump switches between two jobs, heating the cylinder hot and then dropping back to the curve for the radiators. Run the radiators at hot water temperature all day and you lose what the curve was set up to give.
Why the cylinder matters here
Eco Pro fits a cylinder built for heat pumps, well insulated and with a large coil, so the heat pump tops it up in small steps in place of hot bursts. James settles where it sits at the first visit.
Why Is My Air Source Heat Pump Expensive to Run? Start Here
Illustration: a thermostatic radiator valve beside a panel radiator.
Start with how the system has been set: the four questions below need no setting changed, and the answers are the first thing to tell James. If they leave it open, he can compare your settings with the original design on a servicing and optimisation visit, including on systems Eco Pro did not install.
Four things to check or ask about, without changing a setting
- Is weather compensation switched on?
- What maximum flow temperature is set, and does it match the figure in your design paperwork?
- Are the radiator valves open in the rooms you use most?
- How often does the hot water cycle run, and at what temperature?
Designing a Devon Home Around a Low Heat Pump Flow Temperature
Stone and cob cottages, and the 1960s to 1990s bungalows that ran on oil for decades, came with radiators sized for an oil boiler’s hotter water, and those radiators set how low your flow temperature can go. James finds that limit with the £250 plus VAT survey, which comes off the bill in full when you go ahead, and our guide to what a room-by-room heat loss survey settles sets out the method. As a freelance NAPIT MCS assessor, he holds other installers’ systems to the same standard.
From survey to curve
Survey
Heat loss measured room by room at your location’s design temperature.
Radiator schedule
Each radiator checked at the design flow temperature, and upsized where a room falls short.
Commissioning
The curve and the hot water temperature set from the design, and the manufacturer’s warranty registered.
Handover
James shows you the settings that matter and the ones to leave alone.
Frequently Asked Questions
Your design sets it. The MCS and RECC best practice guide suggests a minimum around 30°C and radiators sized for a maximum around 45°C, with weather compensation moving the flow between the two. In an older Devon home, the survey shows where your maximum sits.
James explains how the survey would set your own figure at a free home assessment.
For hot water it is on the low side: the MCS guide suggests 55°C or more for the cylinder. For radiators, 50°C on the coldest design day can be right if the radiators need it, as long as weather compensation brings it down on milder days.
Ask what your radiators would need on a cold day at a free home assessment.
A control that lowers the flow temperature as the outdoor temperature rises, so the radiators get water only as hot as the day needs. MCS requires it to be available on every space heating system, and your installer sets the curve from your design.
Have James explain the curve in plain terms at a free home assessment.
On weather compensation it is designed to run long and low, and the MCS guide notes that big jumps in the set point tend to overshoot. Whether yours runs through the night too depends on your house and tariff, which James covers at handover.
Talk through your tariff and daily routine with James at a free home assessment.
Check the flow settings first: a maximum above the design, or weather compensation switched off, keeps it at the costly end of its range. Then look at the hot water schedule, the radiator valves and your tariff.
Send James a photo of your controller screen when you book a free home assessment.
Your installer set the curve at commissioning against your radiator schedule, so ask them before you change it. We don’t give controller steps for a make we can’t see, because a wrong change shows up as a cold bedroom in January.
Before you press any buttons, put the change to James at a free home assessment.
A heat pump built to reach the hotter water an older radiator system was sized for, which can suit a house where the radiators can’t change. Hotter water still costs more to make, so the survey first checks whether a few larger radiators let a standard heat pump run cooler.
Find out whether a few larger radiators would do at a free home assessment.
Underfloor heating spreads its heat across the whole floor, so it can run on cooler water than an ordinary radiator. It responds unevenly to flow temperature changes, which is why the MCS guide tells installers to take specialist advice when setting up its compensation.
Tell James which floors have underfloor heating at a free home assessment.
Start With a Straight Answer on Your House
One free visit gets you a straight answer on whether your house suits a heat pump, whether the grant applies and a fixed estimate. Go ahead, and the room-by-room survey designs your flow temperature. Already own one that costs too much to run? James will say whether a servicing visit makes sense.
Book my free home assessmentPrefer to talk it through first? Ring 01395 202030. James answers, and he is the person who will price the job.
★★★★★
“The house is finally warm, comfortable, and looking much more modern.”
Georgie Stride · Google review